{"id":6838,"date":"2019-06-15T14:39:18","date_gmt":"2019-06-15T14:39:18","guid":{"rendered":"https:\/\/laweuro.com\/?p=6838"},"modified":"2021-09-22T07:40:16","modified_gmt":"2021-09-22T07:40:16","slug":"regulation-ec-no-79-2009-of-the-european-parliament-and-of-the-council-of-14-january-2009-on-type-approval-of-hydrogen-powered-motor-vehicles-and-amending-directive-2007-46-ec-text-with-eea-releva","status":"publish","type":"post","link":"https:\/\/laweuro.com\/?p=6838","title":{"rendered":"Regulation (EC) No 79\/2009 of the European Parliament and of the Council of 14 January 2009 on type-approval of hydrogen-powered motor vehicles, and amending Directive 2007\/46\/EC (Text with EEA relevance)"},"content":{"rendered":"<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<p class=\"hd-date\">4.2.2009<\/p>\n<\/td>\n<td>\n<p class=\"hd-lg\">EN<\/p>\n<\/td>\n<td>\n<p class=\"hd-ti\">Official Journal of the European Union<\/p>\n<\/td>\n<td>\n<p class=\"hd-oj\">L 35\/32<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr class=\"separator\" \/>\n<p id=\"d1e40-32-1\" class=\"doc-ti\" style=\"text-align: center;\">REGULATION (EC) No 79\/2009 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL<\/p>\n<p class=\"doc-ti\" style=\"text-align: center;\">of 14\u00a0January 2009<\/p>\n<p class=\"doc-ti\" style=\"text-align: center;\"><strong>on type-approval of hydrogen-powered motor vehicles, and amending Directive 2007\/46\/EC<\/strong><\/p>\n<p class=\"doc-ti\" style=\"text-align: center;\">(Text with EEA relevance)<\/p>\n<p class=\"normal\">THE EUROPEAN PARLIAMENT AND THE COUNCIL OF THE EUROPEAN UNION,<\/p>\n<p class=\"normal\">Having regard to the Treaty establishing the European Community, and in particular Article\u00a095 thereof,<\/p>\n<p class=\"normal\">Having regard to the proposal from the Commission,<\/p>\n<p class=\"normal\">Having regard to the opinion of the European Economic and Social Committee\u00a0(<span class=\"super\">1<\/span>),<\/p>\n<p class=\"normal\">Acting in accordance with the procedure laid down in Article\u00a0251 of the Treaty\u00a0(<span class=\"super\">2<\/span>),<\/p>\n<p class=\"normal\">Whereas:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(1)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">The internal market comprises an area without internal frontiers in which the free movement of goods, persons, services and capital is ensured. To that end, a comprehensive Community type-approval system for motor vehicles is in place. The technical requirements for the type-approval of motor vehicles with regard to hydrogen propulsion should be harmonised to avoid the adoption of different requirements in different Member States and to ensure the proper functioning of the internal market while, at the same time, ensuring a high level of environmental protection and public safety.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(2)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">This Regulation is a separate regulation for the purposes of the Community type-approval procedure provided for by Directive 2007\/46\/EC of the European Parliament and of the Council of 5\u00a0September 2007 establishing a framework for the approval of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles (Framework Directive)\u00a0(<span class=\"super\">3<\/span>). Therefore, Annexes\u00a0IV, VI and\u00a0XI to that Directive should be amended accordingly.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(3)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Following the request of the European Parliament, a new regulatory approach has been applied to EC vehicle legislation. This Regulation should therefore lay down only fundamental provisions on requirements for the type-approval of hydrogen systems and components, whereas the technical specifications should be laid down by implementing measures adopted in accordance with Council Decision 1999\/468\/EC of 28\u00a0June 1999 laying down the procedures for the exercise of implementing powers conferred on the Commission\u00a0(<span class=\"super\">4<\/span>).<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(4)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">In particular, the Commission should be empowered to establish the requirements and test procedures relating to new forms of hydrogen storage or usage, additional hydrogen components and the propulsion system. The Commission should also be empowered to establish specific procedures, tests and requirements with regard to the impact protection of hydrogen-powered vehicles and integrated system safety requirements. Since those measures are of general scope and are designed to amend non-essential elements of this Regulation by supplementing it with new non-essential elements, they must be adopted in accordance with the regulatory procedure with scrutiny provided for in Article\u00a05a of Decision 1999\/468\/EC.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(5)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">In the transport sector, one of the main aims should be a greater proportion of more environmentally friendly vehicles. Additional efforts should be undertaken in order to place more of those vehicles on the market. The introduction of vehicles with alternative fuels can significantly improve the quality of urban air and consequently also the state of public health.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(6)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Hydrogen is considered as a clean way of powering vehicles for the future, on the way towards a pollution-free economy based on the reuse of raw materials and on renewable energy resources, as vehicles propelled with hydrogen emit neither carbon-based pollutants nor greenhouse gases. Since hydrogen is an energy vector and not an energy source, the climate-policy value of hydrogen power depends on the source from which the hydrogen is obtained. Care should therefore be taken that hydrogen fuel is produced in a sustainable manner, as far as possible from renewable energy resources, so that the overall environmental balance of introducing hydrogen as a fuel for motor vehicles is positive.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(7)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">The CARS 21 High Level Group stated in its final report that \u2018efforts with a view to increasing international harmonisation of motor vehicle regulations should be maintained where appropriate, with a view to involve the key vehicle markets and to extend harmonisation to areas not yet covered, notably both in the framework of the 1958 and the 1998 Agreements of the UNECE\u2019. In line with this recommendation, the Commission should continue to support the development of internationally harmonised requirements for motor vehicles under the auspices of UNECE. In particular, if a Global Technical Regulation (GTR) on hydrogen and fuel cell vehicles is adopted, the Commission should consider the possibility of adapting the requirements laid down in this Regulation to those established in the GTR.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(8)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Hydrogen mixtures could be used as a transition fuel towards the use of pure hydrogen, to facilitate the introduction of hydrogen-powered vehicles in Member States where the natural gas infrastructure is good. The Commission should therefore develop requirements for the use of mixtures of hydrogen and natural gas\/biomethane, especially a mixing ratio of hydrogen and gas which takes account of technical feasibility and environmental benefits.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(9)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Defining the type-approval framework for hydrogen-powered vehicles would contribute to the confidence in the new technology of potential users and the public at large.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(10)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Therefore, it is necessary to create an adequate framework in order to accelerate the placing on the market of vehicles with innovative propulsion technologies and vehicles which use alternative fuels with a low environmental impact.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(11)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">The majority of manufacturers are making important investments in the development of hydrogen technology and have already started to place such vehicles on the market. In the future, it is likely that the share of hydrogen-powered vehicles in the total fleet will increase. Therefore, the specification of common requirements concerning the safety of hydrogen-powered vehicles is necessary. As manufacturers might follow different approaches to the development of hydrogen-powered vehicles, it is necessary to establish safety requirements in a technology-neutral manner.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(12)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">It is necessary to establish those safety requirements for the hydrogen systems and their components which are necessary in order to obtain type-approval.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(13)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">For type-approval of hydrogen-powered vehicles, it is necessary to establish requirements for the installation of hydrogen systems and their components in the vehicle.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(14)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Owing to the characteristics of the fuel, hydrogen-powered vehicles may require a specific treatment from rescue services. It is therefore necessary to lay down requirements for the clear and rapid identification of such vehicles, allowing the rescue services to be informed of the fuel stored on board the vehicle. Whilst the means of identification should be fit for that purpose it should, as far as possible, avoid being of a nature that is likely to give rise to concern among the public.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(15)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">It is also important to set out the obligations of manufacturers concerning the adoption of appropriate measures to prevent misfuelling of hydrogen-powered vehicles.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(16)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Hydrogen-powered vehicles are unlikely to be successful on the market unless adequate filling-station infrastructure is made available in Europe. The Commission should therefore look into suitable measures to support the establishment of a Europe-wide filling-station network for hydrogen-powered vehicles.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(17)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Innovative small vehicles, designated under EC type-approval legislation as L category vehicles, are considered as early users of hydrogen as a fuel. Introducing hydrogen for these vehicles requires less effort, as the technical challenge and level of investment required is not as high as in the case of M and N category vehicles, as defined in Annex\u00a0II to Directive 2007\/46\/EC. The Commission should, no later than 1\u00a0January 2010, evaluate the possibility of regulating the type-approval of hydrogen L category vehicles.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(18)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Since the objective of this Regulation, namely the achievement of the internal market through the introduction of common technical requirements concerning motor vehicles using hydrogen, cannot be sufficiently achieved by the Member States and can therefore, by reason of its scale, be better achieved at Community level, the Community may adopt measures, in accordance with the principle of subsidiarity, as set out in Article\u00a05 of the Treaty. In accordance with the principle of proportionality, as set out in that Article, this Regulation does not go beyond what is necessary in order to achieve that objective,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">HAVE ADOPTED THIS REGULATION:<\/p>\n<p id=\"d1e225-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a01<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Subject matter<\/p>\n<p class=\"normal\">This Regulation establishes requirements for the type-approval of motor vehicles with regard to hydrogen propulsion and for the type-approval of hydrogen components and hydrogen systems. This Regulation also establishes requirements for the installation of such components and systems.<\/p>\n<p id=\"d1e232-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a02<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Scope<\/p>\n<p class=\"normal\">This Regulation shall apply to:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">1.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen-powered vehicles of categories M and N, as defined in Section A of Annex\u00a0II to Directive 2007\/46\/EC, including impact protection and the electric safety of such vehicles;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">2.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen components designed for motor vehicles of categories M and N, as listed in Annex\u00a0I;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">3.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen systems designed for motor vehicles of categories M and N, including new forms of hydrogen storage or usage.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p id=\"d1e259-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a03<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Definitions<\/p>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0For the purposes of this Regulation, the following definitions shall apply:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">\u2018hydrogen-powered vehicle\u2019 means any motor vehicle that uses hydrogen as fuel to propel the vehicle;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">\u2018propulsion system\u2019 means the internal combustion engine or fuel cell system used to propel the vehicle;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(c)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">\u2018hydrogen component\u2019 means the hydrogen container and all other parts of the hydrogen-powered vehicle that are in direct contact with hydrogen or which form part of a hydrogen system;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(d)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">\u2018hydrogen system\u2019 means an assembly of hydrogen components and connecting parts fitted on hydrogen-powered vehicles, excluding the propulsion systems or auxiliary power units;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(e)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">\u2018maximum allowable working pressure\u2019 (MAWP) means the maximum pressure to which a component is designed to be subjected to and which is the basis for determining the strength of the component under consideration;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(f)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">\u2018nominal working pressure\u2019 (NWP) means, as regards containers, the settled pressure at a uniform temperature of 288K (15\u00a0\u00b0C) for a full container, or as regards other components, the pressure level at which a component typically operates;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(g)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">\u2018inner tank\u2019 means the part of the hydrogen container designed to use liquid hydrogen that contains the cryogenic hydrogen.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0For the purposes of paragraph\u00a01(d), \u2018hydrogen systems\u2019 shall include, <span class=\"italic\">inter alia<\/span>, the following:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">usage monitoring and control systems;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">vehicle interface systems;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(c)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">excess flow systems;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(d)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">overpressure protection systems;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(e)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">heat exchanger failure detection systems.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p id=\"d1e378-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a04<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Obligations of manufacturers<\/p>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0Manufacturers shall demonstrate that all new hydrogen-powered vehicles sold, registered or put into service within the Community and all hydrogen components or hydrogen systems sold or put into service within the Community are type-approved in accordance with this Regulation and its implementing measures.<\/p>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0For the purposes of vehicle type-approval, manufacturers shall equip hydrogen-powered vehicles with hydrogen components and systems that comply with the requirements of this Regulation and its implementing measures and are installed in accordance with this Regulation and its implementing measures.<\/p>\n<p class=\"normal\">3.\u00a0\u00a0\u00a0For the purposes of the type-approval of components and systems, manufacturers shall ensure that hydrogen components and systems comply with the requirements of this Regulation and its implementing measures.<\/p>\n<p class=\"normal\">4.\u00a0\u00a0\u00a0Manufacturers shall provide the approval authorities with appropriate information concerning the vehicle specifications and test conditions.<\/p>\n<p class=\"normal\">5.\u00a0\u00a0\u00a0Manufacturers shall provide information for the purposes of inspection of hydrogen components and systems during the service life of the vehicle.<\/p>\n<p id=\"d1e408-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a05<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">General requirements for hydrogen components and systems<\/p>\n<p class=\"normal\">Manufacturers shall ensure that:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen components and systems function in a correct and safe way and reliably withstand electrical, mechanical, thermal and chemical operating conditions without leaking or visibly deforming;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen systems are protected against over-pressurisation;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(c)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">the materials used for those parts of the hydrogen components and systems which are to be in direct contact with hydrogen are compatible with hydrogen;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(d)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen components and systems reliably withstand expected temperatures and pressures during their expected lifetime;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(e)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen components and systems reliably withstand the range of operating temperatures laid down in the implementing measures;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(f)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen components are marked in accordance with the implementing measures;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(g)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen components with directional flow have the flow direction clearly indicated;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(h)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen components and systems are designed in such a way that they can be installed in accordance with the requirements of Annex\u00a0VI.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p id=\"d1e465-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a06<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Requirements for hydrogen containers designed to use liquid hydrogen<\/p>\n<p class=\"normal\">Hydrogen containers designed to use liquid hydrogen shall be tested in accordance with the test procedures set out in Annex\u00a0II.<\/p>\n<p id=\"d1e472-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a07<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Requirements for hydrogen components, other than containers, designed to use liquid hydrogen<\/p>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0Hydrogen components, other than containers, designed to use liquid hydrogen shall be tested in accordance with the test procedures set out in Annex\u00a0III with regard to their type.<\/p>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0Pressure relief devices shall be designed so as to ensure that the pressure in the inner tank or in any other hydrogen component does not exceed a permissible value. The values shall be set in proportion to the maximum allowable working pressure (MAWP) of the hydrogen system. A safety system for heat exchangers shall be provided for the detection of their failure.<\/p>\n<p id=\"d1e487-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a08<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Requirements for hydrogen containers designed to use compressed (gaseous) hydrogen<\/p>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0Hydrogen containers designed to use compressed (gaseous) hydrogen shall be classified in accordance with point\u00a01 of Annex\u00a0IV.<\/p>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0The containers referred to in paragraph\u00a01 shall be tested in accordance with the test procedures set out in Annex\u00a0IV with regard to their type.<\/p>\n<p class=\"normal\">3.\u00a0\u00a0\u00a0A detailed description of all principal properties of the material and tolerances used in the design of the container shall be provided, including the results of tests to which the material has been subjected.<\/p>\n<p id=\"d1e507-32-1\" class=\"ti-art\">Article\u00a09<\/p>\n<p class=\"sti-art\">Requirements for hydrogen components, other than containers, designed to use compressed (gaseous) hydrogen<\/p>\n<p class=\"normal\">Hydrogen components, other than containers, designed to use compressed (gaseous) hydrogen shall be tested in accordance with the test procedures set out in Annex\u00a0V with regard to their type.<\/p>\n<p id=\"d1e514-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a010<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">General requirements for the installation of hydrogen components and systems<\/p>\n<p class=\"normal\">Hydrogen components and systems shall be installed in accordance with the requirements of Annex\u00a0VI.<\/p>\n<p id=\"d1e521-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a011<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Timetable for application<\/p>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0With effect from 24\u00a0February 2011, national authorities shall refuse to grant:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">EC type-approval or national type-approval in respect of new types of vehicle on grounds relating to hydrogen propulsion, where such vehicle does not comply with the requirements of this Regulation or of its implementing measures; and<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">EC type-approval in respect of new types of hydrogen component or system, where such component or system does not comply with the requirements of this Regulation or of its implementing measures.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0With effect from 24\u00a0February 2012, national authorities shall:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">on grounds relating to hydrogen propulsion, consider certificates of conformity for new vehicles to be no longer valid for the purposes of Article\u00a026 of Directive 2007\/46\/EC, and prohibit the registration, sale and entry into service of such vehicles, where such vehicles do not comply with the requirements of this Regulation or of its implementing measures; and<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">prohibit the sale and entry into service of new hydrogen components or systems, where such components or systems do not comply with the requirements of this Regulation or of its implementing measures.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">3.\u00a0\u00a0\u00a0Without prejudice to paragraphs\u00a01 and\u00a02, and subject to the entry into force of implementing measures adopted pursuant to Article\u00a012(1), if a manufacturer so requests, national authorities shall not:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">on grounds relating to hydrogen propulsion, refuse to grant EC type-approval or national type-approval for new types of vehicle, or EC type-approval for new types of hydrogen component or system, where such vehicle, component or system complies with the requirements of this Regulation and its implementing measures; or<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">prohibit the registration, sale and entry into service of new vehicles or the sale and entry into service of new hydrogen components or systems, where such vehicles, components or systems comply with the requirements of this Regulation and its implementing measures.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p id=\"d1e590-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a012<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Implementing measures<\/p>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0The Commission shall adopt the following implementing measures:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">administrative provisions for the EC type-approval of vehicles, with regard to hydrogen propulsion, and hydrogen components and systems;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">rules on the information to be provided by manufacturers for the purposes of the type-approval and inspection referred to in Article\u00a04(4) and\u00a0(5);<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(c)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">detailed rules for the test procedures set out in Annexes\u00a0II to\u00a0V;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(d)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">detailed rules concerning the requirements for the installation of hydrogen components and systems set out in Annex\u00a0VI;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(e)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">detailed rules concerning the requirements for the safe and reliable functioning of hydrogen components and systems set out in Article\u00a05;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(f)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">detailed rules for the labelling or other means of clear and rapid identification of hydrogen-powered vehicles referred to in point\u00a016 of Annex\u00a0VI.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">Those measures, designed to amend non-essential elements of this Regulation by supplementing it, shall be adopted in accordance with the regulatory procedure with scrutiny referred to in Article\u00a013(2).<\/p>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0The Commission may adopt the following implementing measures:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">specifications for requirements relating to any of the following:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">the use of pure hydrogen or a mixture of hydrogen and natural gas\/biomethane,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">new forms of hydrogen storage or usage,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">the impact protection of vehicles with regard to the integrity of hydrogen components and systems,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">integrated system safety requirements, covering at least the detection of leakage and requirements relating to purge gas,<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">\u2014<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">electrical isolation and electric safety;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">other measures necessary for the application of this Regulation.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">Those measures, designed to amend non-essential elements of this Regulation by supplementing it, shall be adopted in accordance with the regulatory procedure with scrutiny referred to in Article\u00a013(2).<\/p>\n<p id=\"d1e678-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a013<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Committee procedure<\/p>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0The Commission shall be assisted by the Technical Committee \u2014 Motor Vehicles (TCMV) established by Article\u00a040(1) of Directive 2007\/46\/EC.<\/p>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0Where reference is made to this paragraph, Article\u00a05a(1) to\u00a0(4) and Article\u00a07 of Decision 1999\/468\/EC shall apply, having regard to the provisions of Article\u00a08 thereof.<\/p>\n<p id=\"d1e693-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a014<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Amendments to Directive 2007\/46\/EC<\/p>\n<p class=\"normal\">Annexes\u00a0IV, VI and\u00a0XI to Directive 2007\/46\/EC shall be amended in accordance with Annex\u00a0VII to this Regulation.<\/p>\n<p id=\"d1e700-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a015<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Penalties for non-compliance<\/p>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0Member States shall lay down the provisions on penalties applicable for infringement by manufacturers of the provisions of this Regulation and its implementing measures and shall take all measures necessary to ensure that they are implemented. The penalties provided for shall be effective, proportionate and dissuasive. By 24\u00a0August 2010, Member States shall notify those provisions to the Commission, and shall notify it without delay of any subsequent amendment affecting them.<\/p>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0The types of infringement which are subject to a penalty shall include at least the following:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">making false declarations during an approval procedure or a procedure leading to a recall;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">falsifying test results for type-approval or in-use compliance;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(c)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">withholding data or technical specifications which could lead to recall or withdrawal of type-approval;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(d)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">refusal to provide access to information;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(e)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">use of defeat devices.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p id=\"d1e750-32-1\" class=\"ti-art\" style=\"text-align: center;\">Article\u00a016<\/p>\n<p class=\"sti-art\" style=\"text-align: center;\">Entry into force<\/p>\n<p class=\"normal\">This Regulation shall enter into force on the 20th day following its publication in the <span class=\"italic\">Official Journal of the European Union<\/span>.<\/p>\n<p class=\"normal\">It shall apply from 24\u00a0February 2011, with the exception of Article\u00a011(3) and Article\u00a012, which shall apply from the date of entry into force of this Regulation, and Article\u00a011(2), which shall apply from the date set out therein.<\/p>\n<div class=\"final\">\n<p class=\"normal\">This Regulation shall be binding in its entirety and directly applicable in all Member States.<\/p>\n<p class=\"normal\">Done at Strasbourg, 14\u00a0January 2009.<\/p>\n<div class=\"signatory\">\n<p class=\"signatory\"><span class=\"italic\">For the European Parliament<\/span><\/p>\n<p class=\"signatory\"><span class=\"italic\">The President<\/span><\/p>\n<p class=\"signatory\">H.-G. P\u00d6TTERING<\/p>\n<\/div>\n<div class=\"signatory\">\n<p class=\"signatory\"><span class=\"italic\">For the Council<\/span><\/p>\n<p class=\"signatory\"><span class=\"italic\">The President<\/span><\/p>\n<p class=\"signatory\">A. VONDRA<\/p>\n<\/div>\n<\/div>\n<hr class=\"note\" \/>\n<p class=\"note\">(<span class=\"super\">1<\/span>)\u00a0\u00a0Opinion delivered on 9\u00a0July 2008.<\/p>\n<p class=\"note\">(<span class=\"super\">2<\/span>)\u00a0\u00a0Opinion of the European Parliament of 3\u00a0September 2008 (not yet published in the Official Journal) and Council Decision of 16\u00a0December 2008.<\/p>\n<p class=\"note\">(<span class=\"super\">3<\/span>)\u00a0\u00a0OJ\u00a0L\u00a0263, 9.10.2007, p.\u00a01.<\/p>\n<p class=\"note\">(<span class=\"super\">4<\/span>)\u00a0\u00a0OJ\u00a0L\u00a0184, 17.7.1999, p.\u00a023.<\/p>\n<hr class=\"doc-sep\" \/>\n<div id=\"L_2009035EN.01003801\">\n<p id=\"d1e32-38-1\" class=\"doc-ti\" style=\"text-align: center;\">ANNEX\u00a0I<\/p>\n<p class=\"doc-ti\" style=\"text-align: center;\">List of hydrogen components to be type-approved<\/p>\n<p class=\"normal\">Where fitted to a hydrogen-powered vehicle, the following hydrogen components must be type-approved:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">components designed to use liquid hydrogen:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">1.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">container;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">2.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">automatic shut-off valve;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">3.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">check valve or non-return valve (if used as a safety device);<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">4.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">flexible fuel line (if upstream of first automatic shut-off valve or other safety devices);<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">5.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">heat exchanger;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">6.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">manual or automatic valve;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">7.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">pressure regulator;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">8.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">pressure relief valve;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">9.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">pressure, temperature and flow sensors (if used as a safety device);<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">10.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">refuelling connection or receptacle;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">11.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen leakage detection sensors;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">components designed to use compressed (gaseous) hydrogen with a nominal working pressure of over 3,0 MPa:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">1.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">container;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">2.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">automatic shut-off valve;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">3.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">container assembly;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">4.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">fittings;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">5.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">flexible fuel line;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">6.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">heat exchanger;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">7.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen filter;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">8.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">manual or automatic valve;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">9.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">non-return valve;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">10.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">pressure regulator;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">11.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">pressure relief device;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">12.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">pressure relief valve;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">13.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">refuelling connection or receptacle;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">14.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">removable storage system connector;<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">15.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">pressure, temperature, hydrogen and flow sensors (if used as a safety device);<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">16.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">hydrogen leakage detection sensors.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<hr class=\"doc-sep\" \/>\n<div id=\"L_2009035EN.01003901\">\n<p id=\"d1e32-39-1\" class=\"doc-ti\" style=\"text-align: center;\">ANNEX\u00a0II<\/p>\n<p class=\"doc-ti\" style=\"text-align: center;\">Applicable test procedures for hydrogen containers designed to use liquid hydrogen<\/p>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"100%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Type of test<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Burst test<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Bonfire test<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Maximum filling level test<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Pressure test<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Leak test<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">The test procedures to be applied for the type-approval of hydrogen containers designed to use liquid hydrogen must include:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Burst test: the purpose of the test is to provide evidence that the hydrogen container does not fail before a specified level of high pressure, the burst pressure (safety factor multiplied by the MAWP) is exceeded. In order to obtain type-approval, the value of the real burst pressure during the test must exceed the required minimum burst pressure.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Bonfire test: the purpose of the test is to provide evidence that the container with its fire protection system does not burst when tested under specified fire conditions.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(c)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Maximum filling level test: the purpose of the test is to provide evidence that the system, which prevents overfilling of the container, works adequately and that the level of hydrogen during the filling procedure never causes the opening of the pressure relief devices.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(d)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Pressure test: the purpose of the test is to provide evidence that the hydrogen container can withstand a specified level of high pressure. In order to prove this, the container is pressurised to a given value for a specified time. After the test the container must not show any signs of visible permanent deformation or visible leaks.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(e)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Leak test: the purpose of the test is to provide evidence that the hydrogen container does not show evidence of leakage under specified conditions. In order to prove this, the container is pressurised to its nominal working pressure. It must not show any evidence of leakage detected through cracks, pores or other similar defects.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<hr class=\"doc-sep\" \/>\n<div id=\"L_2009035EN.01004001\">\n<p id=\"d1e92-40-1\" class=\"doc-ti\" style=\"text-align: center;\">ANNEX\u00a0III<\/p>\n<p class=\"doc-ti\" style=\"text-align: center;\">Applicable test procedures for hydrogen components, other than containers, designed to use liquid hydrogen<\/p>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"10%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"8%\" \/>\n<col width=\"10%\" \/>\n<col width=\"9%\" \/>\n<col width=\"9%\" \/>\n<col width=\"5%\" \/>\n<col width=\"10%\" \/>\n<col width=\"7%\" \/>\n<col width=\"12%\" \/>\n<col width=\"6%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" colspan=\"11\" valign=\"top\">\n<p class=\"tbl-hdr\">TYPE OF TEST<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">HYDROGEN COMPONENT<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Pressure test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">External leakage test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Endurance test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Operational test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Corrosion resistance test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Resistance to dry-heat test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Ozone ageing test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Temperature cycle test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Pressure cycle test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Hydrogen compatibility test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Seat leakage test<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Pressure relief devices<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Valves<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Heat exchangers<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Refuelling connections or receptacles<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Pressure regulators<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Sensors<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Flexible fuel lines<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">Subject to specific requirements in relation to any of the hydrogen components, the test procedures to be applied for the type-approval of hydrogen components, other than containers, designed to use liquid hydrogen must include:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Pressure test: the purpose of the test is to provide evidence that the hydrogen components can withstand a level of pressure which is higher than the working pressure of the component. The hydrogen components must not show any visible evidence of leak, deformation, rupture or cracks when the pressure is increased to a certain level.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">External leakage test: the purpose of the test is to provide evidence that the hydrogen components are free from external leakage. The hydrogen components must not show evidence of porosity.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(c)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Endurance test: the purpose of the test is to provide evidence that the hydrogen components are capable of continuous reliable operation. The test consists of carrying out a specific number of test cycles for the hydrogen component under specified temperature and pressure conditions. A test cycle means the normal operation (i.e. one opening and one closing) of the hydrogen component.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(d)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Operational test: the purpose of the test is to provide evidence that the hydrogen components are capable of operating reliably.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(e)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Corrosion resistance test: the purpose of the test is to provide evidence that the hydrogen components are capable of resisting corrosion. In order to prove this, the hydrogen components are submitted to contact with specified chemicals.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(f)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Resistance to dry-heat test: the purpose of the test is to provide evidence that the non-metallic hydrogen components are capable of resisting high temperature. In order to prove this, the components are exposed to air at the maximum operating temperature.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(g)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Ozone ageing test: the purpose of the test is to provide evidence that the non-metallic hydrogen components are capable of resisting ageing due to ozone. In order to prove this, the components are exposed to air with high ozone concentration.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(h)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Temperature cycle test: the purpose of the test is to provide evidence that the hydrogen components are capable of resisting high variations of temperature. In order to prove this, the hydrogen components are submitted to a temperature cycle of specified duration from the minimum operating temperature up to the maximum operating temperature.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(i)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Pressure cycle test: the purpose of the test is to provide evidence that the hydrogen components are capable of resisting high variations of pressure. In order to prove this, the hydrogen components are submitted to a pressure change from atmospheric pressure to the maximum allowable working pressure (MAWP) and then back to atmospheric pressure within a short period of time.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(j)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Hydrogen compatibility test: the purpose of the test is to provide evidence that metallic hydrogen components (i.e. cylinders and\u00a0valves) are not susceptible to hydrogen embrittlement. In hydrogen components that are subjected to frequent load cycles, conditions that can lead to local fatigue and the initiation and propagation of fatigue cracks in the structure must be avoided.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(k)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Seat leakage test: the purpose of the test is to provide evidence that hydrogen components are free from leakage while installed in the hydrogen system.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<hr class=\"doc-sep\" \/>\n<div id=\"L_2009035EN.01004201\">\n<p id=\"d1e74-42-1\" class=\"doc-ti\" style=\"text-align: center;\">ANNEX\u00a0IV<\/p>\n<p class=\"doc-ti\" style=\"text-align: center;\">Applicable test procedures for hydrogen containers designed to use compressed (gaseous) hydrogen<\/p>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"31%\" \/>\n<col width=\"28%\" \/>\n<col width=\"14%\" \/>\n<col width=\"14%\" \/>\n<col width=\"14%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" rowspan=\"2\" valign=\"top\">\n<p class=\"tbl-hdr\">Type of test<\/p>\n<\/td>\n<td class=\"table\" colspan=\"4\" valign=\"top\">\n<p class=\"tbl-hdr\">Applicable to container type<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">1<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">2<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">3<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">4<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Burst test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Ambient temperature pressure cycle test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">LBB performance test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Bonfire test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Penetration test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Chemical exposure test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Composite flaw tolerance test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Accelerated stress rupture test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Extreme temperature pressure cycle test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Impact damage test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Leak test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Permeation test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Boss torque test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Hydrogen gas cycle test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0Classification of hydrogen containers designed to use compressed (gaseous) hydrogen:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"20%\" \/>\n<col width=\"80%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">Type 1<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Seamless metallic container<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">Type 2<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Hoop wrapped container with a seamless metallic liner<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">Type 3<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Fully wrapped container with a seamless or welded metallic liner<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">Type 4<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Fully wrapped container with a non-metallic liner.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0The test procedures to be applied for the type-approval of hydrogen containers designed to use compressed (gaseous) hydrogen must include:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(a)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Burst test: the purpose of the test is to provide the value of the pressure at which the container bursts. In order to prove this, the container is pressurised to a given value, which must be higher than the nominal working pressure of the container. The burst pressure of the container must exceed a specified pressure. The burst pressure of the container must be recorded and be kept by the manufacturer throughout the service life of the container.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(b)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Ambient temperature pressure cycle test: the purpose of the test is to provide evidence that the hydrogen container is capable of resisting high variations of pressure. In order to prove this, pressure cycles are carried out on the container until a failure occurs or until a specified number of cycles is reached by increasing and decreasing the pressure to a specified value. The containers must not fail before reaching a specified number of cycles. The number of cycles to failure, along with the location and description of the failure, must be documented. The manufacturer must keep the results throughout the service life of the container.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(c)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Leak before break (LBB) performance test: the purpose of the test is to provide evidence that the hydrogen container fails by leakage before rupture. In order to prove this, pressure cycles are carried out on the container by increasing and decreasing the pressure to a specified value. The containers tested must either fail by leakage or exceed a specified number of test cycles without failure. The number of cycles to failure, along with the location and description of the failure, must be recorded.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(d)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Bonfire test: the purpose of the test is to provide evidence that the container with its fire protection system does not burst when tested under specified fire conditions. The container, pressurised to working pressure, must only vent through the pressure relief device and must not rupture.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(e)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Penetration test: the purpose of the test is to provide evidence that the container does not rupture when penetrated by a bullet. In order to prove this, the complete container with its protective coating is pressurised and penetrated by a bullet. The container must not rupture.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(f)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Chemical exposure test: the purpose of the test is to provide evidence that the container can withstand exposure to specified chemical substances. In order to prove this, the container is exposed to various chemical solutions. The pressure of the container is increased to a given value and a burst test as referred to under point\u00a0(a) is carried out. The container must achieve a specified burst pressure, which must be recorded.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(g)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Composite flaw tolerance test: the purpose of the test is to provide evidence that the hydrogen container is capable of resisting exposure to high pressure. In order to prove this, flaws of specified geometry are cut into the container sidewall and a specified number of pressure cycles carried out. The container must not leak or rupture within a number of cycles, but may fail by leakage during the remaining test cycles. The number of cycles to failure, along with the location and description of the failure, must be recorded.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(h)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Accelerated stress rupture test: the purpose of the test is to provide evidence that the hydrogen container is capable of resisting exposure to high pressure and high temperatures at the limit of the allowable operating range for an extended period of time. In order to prove this, the container is exposed for a specified time to specified pressure and temperature conditions, and subsequently undergoes a burst test as referred to under point\u00a0(a). The container must achieve a specified burst pressure.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(i)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Extreme temperature pressure cycle test: the purpose of the test is to provide evidence that the hydrogen container can withstand variations of pressure under different temperature conditions. In order to prove this, the container, free of any protective coating, is hydrostatically cycle tested by being subjected to extreme ambient conditions, and subsequently undergoes a burst test and a leak test as referred to under points\u00a0(a) and\u00a0(k). When cycle tested, the containers must not show evidence of rupture, leakage or fibre unravelling. The containers must not burst at a specified pressure.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(j)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Impact damage test: the purpose of the test is to provide evidence that the hydrogen container remains operational after being submitted to the specified mechanical impacts. In order to prove this, the container is subjected to a drop test, and a specified number of pressure cycles are carried out. The container must not leak or rupture within a specified number of cycles, but may fail by leakage during the remaining test cycles.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(k)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Leak test: the purpose of the test is to provide evidence that the hydrogen container does not show evidence of leakage under the specified conditions. In order to prove this, the container is pressurised to its nominal working pressure. It must not show any evidence of leakage detected through cracks, pores or similar defects.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(l)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Permeation test: the purpose of the test is to provide evidence that the hydrogen container does not permeate more than a specified rate. In order to prove this, the container is pressurised with hydrogen gas to nominal working pressure and then monitored for permeation in a closed chamber for a specified time under specified temperature conditions.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(m)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Boss torque test: the purpose of the test is to provide evidence that the hydrogen container is capable of resisting the specified torque. In order to prove this, a torque is applied to the container from different directions. Then a burst test and a leak test as referred to under points\u00a0(a) and\u00a0(k) are carried out. The container must meet the burst and leak test requirements. The applied torque, leakage and burst pressure must be recorded.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">(n)<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Hydrogen gas cycle test: the purpose of the test is to provide evidence that the hydrogen container is capable of resisting high variations of pressure when hydrogen gas is used. In order to prove this, the container is subjected to a number of pressure cycles with the use of hydrogen gas and a leak test as referred to under point\u00a0(k). Deteriorations, such as fatigue cracking or electrostatic discharge of the container, are inspected. The container must meet leak test requirements. The container must be free of any deterioration, such as fatigue cracking or electrostatic discharge.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<hr class=\"doc-sep\" \/>\n<div id=\"L_2009035EN.01004401\">\n<p id=\"d1e109-44-1\" class=\"doc-ti\" style=\"text-align: center;\">ANNEX\u00a0V<\/p>\n<p class=\"doc-ti\" style=\"text-align: center;\">Applicable test procedures for hydrogen components, other than containers, designed to use compressed (gaseous) hydrogen<\/p>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"18%\" \/>\n<col width=\"13%\" \/>\n<col width=\"16%\" \/>\n<col width=\"15%\" \/>\n<col width=\"13%\" \/>\n<col width=\"13%\" \/>\n<col width=\"13%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" colspan=\"6\" valign=\"top\">\n<p class=\"tbl-hdr\">TYPE OF TEST<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">HYDROGEN COMPONENT<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Material tests<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Corrosion resistance test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Endurance test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Pressure cycle test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Internal leakage test<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">External leakage test<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Pressure relief devices<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Automatic valves<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Manual valves<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Non-return valves<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Pressure relief valves<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Heat exchangers<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Refuelling connections or receptacles<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Pressure regulators<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Sensors for hydrogen systems<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Flexible fuel lines<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Fittings<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Hydrogen filters<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Removable storage system connectors<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"image\"><img decoding=\"async\" src=\"https:\/\/laweuro.com\/wp-content\/uploads\/2019\/06\/resource-69.jpg\" alt=\"Image\" width=\"7.5\" height=\"8\" \/><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">Subject to specific requirements for any of the hydrogen components, the test procedures to be applied for the type-approval of hydrogen components, other than containers, designed to use compressed (gaseous) hydrogen must include:<\/p>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0Material tests:<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">1.1.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Hydrogen compatibility test set out in point\u00a0(j) of Annex\u00a0III.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">1.2.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Ageing test: the purpose of the test is to check whether the non-metallic material used in a hydrogen component can withstand ageing. No visible cracking of the test samples is allowed.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"4%\" \/>\n<col width=\"96%\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td valign=\"top\">\n<p class=\"normal\">1.3.<\/p>\n<\/td>\n<td valign=\"top\">\n<p class=\"normal\">Ozone compatibility test: the purpose of the test is to check whether the elastomer material of a hydrogen component is compatible with ozone exposure. No visible cracking of the test samples is allowed.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0Corrosion resistance test set out in point\u00a0(e) of Annex\u00a0III.<\/p>\n<p class=\"normal\">3.\u00a0\u00a0\u00a0Endurance test set out in point\u00a0(c) of Annex\u00a0III.<\/p>\n<p class=\"normal\">4.\u00a0\u00a0\u00a0Pressure cycle test set out in point\u00a0(i) of Annex\u00a0III. The hydrogen components must not show visible signs of deformation or extrusion and must fulfil the requirements of the internal and external leakage tests.<\/p>\n<p class=\"normal\">5.\u00a0\u00a0\u00a0Internal leakage test: the purpose of the test is to provide evidence that the specified hydrogen components are free from internal leakage. In order to prove this, the hydrogen components are pressurised under different temperature conditions and observed for leakage. The hydrogen components must stay bubble free and must not leak internally at a higher rate than a specified number.<\/p>\n<p class=\"normal\">6.\u00a0\u00a0\u00a0External leakage test set out in point\u00a0(b) of Annex\u00a0III.<\/p>\n<\/div>\n<hr class=\"doc-sep\" \/>\n<div id=\"L_2009035EN.01004501\">\n<p id=\"d1e32-45-1\" class=\"doc-ti\" style=\"text-align: center;\">ANNEX\u00a0VI<\/p>\n<p class=\"doc-ti\" style=\"text-align: center;\">Requirements for the installation of hydrogen components and systems<\/p>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0The hydrogen system must be installed in such a way that it is protected against damage.<\/p>\n<p class=\"normal\">It must be isolated from heat sources in the vehicle.<\/p>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0The hydrogen container may only be removed for replacement with another hydrogen container, for the purpose of refuelling or for maintenance.<\/p>\n<p class=\"normal\">In the case of an internal combustion engine, the container must not be installed in the engine compartment of the vehicle.<\/p>\n<p class=\"normal\">It must be adequately protected against all kinds of corrosion.<\/p>\n<p class=\"normal\">3.\u00a0\u00a0\u00a0Measures must be taken to prevent misfuelling of the vehicle and hydrogen leakage during refilling and to make sure that the removal of a removable hydrogen storage system is done safely.<\/p>\n<p class=\"normal\">4.\u00a0\u00a0\u00a0The refuelling connection or receptacle must be secured against maladjustment and protected from dirt and water. The refuelling connection or receptacle must be integrated with a non-return valve or a valve with the same function. If the refuelling connection is not mounted directly on the container, the refuelling line must be secured by a non-return valve or a valve with the same function which is mounted directly on or within the container.<\/p>\n<p class=\"normal\">5.\u00a0\u00a0\u00a0The hydrogen container must be mounted and fixed so that the specified accelerations can be absorbed without damage to the safety related parts when the hydrogen containers are full.<\/p>\n<p class=\"normal\">6.\u00a0\u00a0\u00a0The hydrogen fuel supply lines must be secured with an automatic shut-off valve mounted directly on or within the container. The valve shall close if a malfunction of the hydrogen system so requires or any other event that results in the leakage of hydrogen occurs. When the propulsion system is switched off, the fuel supply from the container to the propulsion system must be switched off and remain closed until the system is required to operate.<\/p>\n<p class=\"normal\">7.\u00a0\u00a0\u00a0In the event of an accident, the automatic shut-off valve mounted directly on or within the container shall interrupt the flow of gas from the container.<\/p>\n<p class=\"normal\">8.\u00a0\u00a0\u00a0Hydrogen components, including any protective materials that form part of such components, must not project beyond the outline of the vehicle or protective structure. This does not apply to a hydrogen component which is adequately protected and no part of which is located outside this protective structure.<\/p>\n<p class=\"normal\">9.\u00a0\u00a0\u00a0The hydrogen system must be installed in such a way that it is protected against damage so far as is reasonably practicable, such as damage due to moving vehicle components, impacts, grit, the loading or unloading of the vehicle or the shifting of loads.<\/p>\n<p class=\"normal\">10.\u00a0\u00a0\u00a0Hydrogen components must not be located near the exhaust of an internal combustion engine or other heat source, unless such components are adequately shielded against heat.<\/p>\n<p class=\"normal\">11.\u00a0\u00a0\u00a0The ventilating or heating system for the passenger compartment and places where leakage or accumulation of hydrogen is possible must be designed so that hydrogen is not drawn into the vehicle.<\/p>\n<p class=\"normal\">12.\u00a0\u00a0\u00a0In the event of an accident, it must be ensured so far as is reasonably practicable that the pressure relief device and the associated venting system remain capable of functioning. The venting system of the pressure relief device must be adequately protected against dirt and water.<\/p>\n<p class=\"normal\">13.\u00a0\u00a0\u00a0The passenger compartment of the vehicle must be separated from the hydrogen system in order to avoid accumulation of hydrogen. It must be ensured that any fuel leaking from the container or its accessories does not escape to the passenger compartment of the vehicle.<\/p>\n<p class=\"normal\">14.\u00a0\u00a0\u00a0Hydrogen components that could leak hydrogen within the passenger or luggage compartment or other non-ventilated compartment must be enclosed by a gas-tight housing or by an equivalent solution as specified in the implementing measures.<\/p>\n<p class=\"normal\">15.\u00a0\u00a0\u00a0Electrically operated devices containing hydrogen must be insulated in such a manner that no current passes through hydrogen containing parts in order to prevent electric sparks in the case of a fracture.<\/p>\n<p class=\"normal\">Metallic components of the hydrogen system must have electrical continuity with the vehicle\u2019s earth.<\/p>\n<p class=\"normal\">16.\u00a0\u00a0\u00a0Labels or other means of identification must be used to indicate to rescue services that the vehicle is powered by hydrogen and that liquid or compressed (gaseous) hydrogen is used.<\/p>\n<\/div>\n<hr class=\"doc-sep\" \/>\n<div id=\"L_2009035EN.01004601\">\n<p id=\"d1e32-46-1\" class=\"doc-ti\" style=\"text-align: center;\">ANNEX\u00a0VII<\/p>\n<p class=\"doc-ti\" style=\"text-align: center;\">Amendments to Directive 2007\/46\/EC<\/p>\n<p class=\"normal\">Directive 2007\/46\/EC is hereby amended as follows:<\/p>\n<p class=\"normal\">1.\u00a0\u00a0\u00a0In Part I of Annex\u00a0IV, the following row shall be added to the table:<\/p>\n<div>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"6%\" \/>\n<col width=\"9%\" \/>\n<col width=\"11%\" \/>\n<col width=\"10%\" \/>\n<col width=\"14%\" \/>\n<col width=\"6%\" \/>\n<col width=\"6%\" \/>\n<col width=\"6%\" \/>\n<col width=\"6%\" \/>\n<col width=\"6%\" \/>\n<col width=\"6%\" \/>\n<col width=\"6%\" \/>\n<col width=\"6%\" \/>\n<col width=\"6%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" rowspan=\"2\" valign=\"top\">\n<p class=\"tbl-hdr\">Item<\/p>\n<\/td>\n<td class=\"table\" rowspan=\"2\" valign=\"top\">\n<p class=\"tbl-hdr\">Subject<\/p>\n<\/td>\n<td class=\"table\" rowspan=\"2\" valign=\"top\">\n<p class=\"tbl-hdr\">Regulatory act reference<\/p>\n<\/td>\n<td class=\"table\" rowspan=\"2\" valign=\"top\">\n<p class=\"tbl-hdr\">Official Journal reference<\/p>\n<\/td>\n<td class=\"table\" colspan=\"10\" valign=\"top\">\n<p class=\"tbl-hdr\">Applicability<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">1<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">2<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">3<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">N<span class=\"sub\">1<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">N<span class=\"sub\">2<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">N<span class=\"sub\">3<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">1<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">2<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">3<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">4<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">\u201862<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Hydrogen system<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Regulation (EC) No 79\/2009<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">L\u00a035, 4.2.2009, p.\u00a032<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">X<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">X<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">X<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">X<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">X<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">X\u2019<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"normal\">2.\u00a0\u00a0\u00a0In the Appendix to Part I of Annex\u00a0IV, the following row shall be added to the table:<\/p>\n<div>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"14%\" \/>\n<col width=\"22%\" \/>\n<col width=\"27%\" \/>\n<col width=\"24%\" \/>\n<col width=\"14%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Subject<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Regulatory act reference<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Official Journal reference<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">1<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">\u201862<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Hydrogen system<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Regulation (EC) No 79\/2009<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">L\u00a035, 4.2.2009, p.\u00a032<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">X\u2019<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"normal\">3.\u00a0\u00a0\u00a0In the Appendix to Annex\u00a0VI, the following row shall be added to the table:<\/p>\n<div>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"13%\" \/>\n<col width=\"20%\" \/>\n<col width=\"25%\" \/>\n<col width=\"18%\" \/>\n<col width=\"25%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Subject<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Regulatory act reference (<span class=\"super\">1<\/span>)<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">As amended by<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Applicable to versions<\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">\u201862.<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Hydrogen system<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Regulation (EC) No 79\/2009\u2019<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"normal\">4.\u00a0\u00a0\u00a0In Appendix\u00a01 to Annex\u00a0XI, the following row shall be added to the table:<\/p>\n<div>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"12%\" \/>\n<col width=\"19%\" \/>\n<col width=\"23%\" \/>\n<col width=\"12%\" \/>\n<col width=\"12%\" \/>\n<col width=\"12%\" \/>\n<col width=\"12%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Item<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Subject<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Regulatory act reference<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">1<\/span> \u2264 2\u00a0500 (<span class=\"super\">1<\/span>) kg<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">1<\/span> &gt; 2\u00a0500 (<span class=\"super\">1<\/span>) kg<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">2<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">3<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">\u201862<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Hydrogen system<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Regulation (EC) No 79\/2009<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Q<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">G\u00a0+\u00a0Q<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">G\u00a0+\u00a0Q<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">G\u00a0+\u00a0Q\u2019<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"normal\">5.\u00a0\u00a0\u00a0In Appendix\u00a02 to Annex\u00a0XI, the following row shall be added to the table:<\/p>\n<div>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"7%\" \/>\n<col width=\"11%\" \/>\n<col width=\"14%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Item<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Subject<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Regulatory act reference<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">1<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">2<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">3<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">N<span class=\"sub\">1<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">N<span class=\"sub\">2<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">N<span class=\"sub\">3<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">1<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">2<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">3<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">4<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">\u201862<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Hydrogen system<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Regulation (EC) No 79\/2009<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">A<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">A<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">A<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">A<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">A<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">A\u2019<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"normal\">6.\u00a0\u00a0\u00a0In Appendix\u00a03 to Annex\u00a0XI, the following row shall be added to the table:<\/p>\n<div>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"18%\" \/>\n<col width=\"29%\" \/>\n<col width=\"36%\" \/>\n<col width=\"18%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Item<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Subject<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Regulatory act reference<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">1<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">\u201862<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Hydrogen system<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Regulation (EC) No 79\/2009<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">X\u2019<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"normal\">7.\u00a0\u00a0\u00a0In Appendix\u00a04 to Annex\u00a0XI, the following row shall be added to the table:<\/p>\n<div>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"7%\" \/>\n<col width=\"12%\" \/>\n<col width=\"15%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/>\n<col width=\"7%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Item<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Subject<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Regulatory act reference<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">2<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">M<span class=\"sub\">3<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">N<span class=\"sub\">1<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">N<span class=\"sub\">2<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">N<span class=\"sub\">3<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">1<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">2<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">3<\/span><\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">O<span class=\"sub\">4<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">\u201862<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Hydrogen system<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Regulation (EC) No 79\/2009<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Q<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Q<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Q<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Q<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Q\u2019<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"normal\">\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"normal\">8.\u00a0\u00a0\u00a0In Appendix\u00a05 to Annex\u00a0XI, the following row shall be added to the table:<\/p>\n<div>\n<table class=\"table\" border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"16%\" \/>\n<col width=\"26%\" \/>\n<col width=\"32%\" \/>\n<col width=\"26%\" \/> <\/colgroup>\n<tbody>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Item<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Subject<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Regulatory act reference<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-hdr\">Mobile crane of category N<span class=\"sub\">3<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"table\">\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">\u201862<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Hydrogen system<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">Regulation (EC) No 79\/2009<\/p>\n<\/td>\n<td class=\"table\" valign=\"top\">\n<p class=\"tbl-txt\">X\u2019<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"social-share-buttons\"><a href=\"https:\/\/www.facebook.com\/sharer\/sharer.php?u=https:\/\/laweuro.com\/?p=6838\" target=\"_blank\" rel=\"noopener\">Facebook<\/a><a href=\"https:\/\/twitter.com\/intent\/tweet?url=https:\/\/laweuro.com\/?p=6838&text=Regulation+%28EC%29+No+79%2F2009+of+the+European+Parliament+and+of+the+Council+of+14+January+2009+on+type-approval+of+hydrogen-powered+motor+vehicles%2C+and+amending+Directive+2007%2F46%2FEC+%28Text+with+EEA+relevance%29\" target=\"_blank\" rel=\"noopener\">Twitter<\/a><a href=\"https:\/\/www.linkedin.com\/shareArticle?url=https:\/\/laweuro.com\/?p=6838&title=Regulation+%28EC%29+No+79%2F2009+of+the+European+Parliament+and+of+the+Council+of+14+January+2009+on+type-approval+of+hydrogen-powered+motor+vehicles%2C+and+amending+Directive+2007%2F46%2FEC+%28Text+with+EEA+relevance%29\" target=\"_blank\" rel=\"noopener\">LinkedIn<\/a><a href=\"https:\/\/pinterest.com\/pin\/create\/button\/?url=https:\/\/laweuro.com\/?p=6838&description=Regulation+%28EC%29+No+79%2F2009+of+the+European+Parliament+and+of+the+Council+of+14+January+2009+on+type-approval+of+hydrogen-powered+motor+vehicles%2C+and+amending+Directive+2007%2F46%2FEC+%28Text+with+EEA+relevance%29\" target=\"_blank\" rel=\"noopener\">Pinterest<\/a><\/div>","protected":false},"excerpt":{"rendered":"<p>4.2.2009 EN Official Journal of the European Union L 35\/32 REGULATION (EC) No 79\/2009 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 14\u00a0January 2009 on type-approval of hydrogen-powered motor vehicles, and amending Directive 2007\/46\/EC (Text with EEA relevance) THE&hellip;<\/p>\n<p class=\"more-link-p\"><a class=\"more-link\" href=\"https:\/\/laweuro.com\/?p=6838\">Read more &rarr;<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[8],"tags":[],"class_list":["post-6838","post","type-post","status-publish","format-standard","hentry","category-eu-law"],"_links":{"self":[{"href":"https:\/\/laweuro.com\/index.php?rest_route=\/wp\/v2\/posts\/6838","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/laweuro.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/laweuro.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/laweuro.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/laweuro.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6838"}],"version-history":[{"count":2,"href":"https:\/\/laweuro.com\/index.php?rest_route=\/wp\/v2\/posts\/6838\/revisions"}],"predecessor-version":[{"id":16500,"href":"https:\/\/laweuro.com\/index.php?rest_route=\/wp\/v2\/posts\/6838\/revisions\/16500"}],"wp:attachment":[{"href":"https:\/\/laweuro.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6838"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/laweuro.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=6838"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/laweuro.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=6838"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}